117
subtracted from the pre-capacitance voltage to get a charge rate. If this charge rate is
within the window of the PD signatures, the device is considered to be discovered.
And then, click to carry into effect.
Port: The index of PoE ports.
Enable State: Check it to enable the PoE function to the port.
Power Limit From: Check it to decide the power limit method.
Classification: When this check box is ticked, the system will limit the power
supply to the powered device in accordance with the related class.
Legacy: Check it to support the legacy power devices.
Priority: Pull down the selection menu item to choose the priority of power supplying.
Port Limit (<15400) mW: User can key in the power limit value which is under 15.4
Watts.
Mode: Displays the operating mode of the port.
Current (mA): Displays the operating current of the port.
Voltage (V): Displays the operating voltage of the port.
Power (mW): Displays the power consumption of the port.
Determined Class: Displays the PD’s class.