103
Enable Couple Ring string label.
Couple Port: Assign the member port which is connected to the other ring group.
Control Port: When the Enable Couple Ring checkbox is ticked, you have to
assign the control port to form a couple-ring group between the two X-rings.
Enable Dual Homing: Set up one of the ports on the switch to be the Dual Homing
port. For a switch, there is only one Dual Homing port. Dual Homing function works
only when the X-Ring function enabled.
And then, click to have the configuration take effect.
X-ring Interface
[NOTE]
1. When the X-Ring function enabled, the user must disable the RSTP. The
X-Ring function and RSTP function cannot exist on a switch at the same
time.
2. Remember to execute the “Save Configuration” action, otherwise the new
configuration will lose when switch powers off.
Page view 109